emka TECHNOLOGIES' hardware and software products for preclinical research
    what we do

  our products
  software software
  hardware hardware
    isolated organ systems
     tissue baths
     ios4 automate
     isolated heart
     vessel myographs
     stimulation
     thermal regulation
     perfusion
    pulmonary systems
    amplifiers
    usb acquisition
    noninvasive telemetry
    easyMATRIX
    implantable telemetry
    rodent telemetry
    drug delivery implant
    flowmeters
    transducers
    pv systems
    food intake monitoring
    rodent ecg restrainer
    noninvasive ecg & bp
    nibp from small rodents
  21 cfr part 11 21 cfr part 11
  arrange a demo arrange a demo
  request a quote request a quote
  latest projects latest projects
 
4-channel asynchronous stimulator
 

Download the 4-channel asynchronous stimulator product sheet.emka TECHNOLOGIES’ 4-channel asynchronous stimulator is the latest model from our laboratory line of stimulators for experiments on isolated organs or tissues. Our unique line has been used successfully for over 10 years by many laboratories worldwide.

The asynchronous stimulator generates a constant current or a constant voltage on each of up to 4 channels independently.

The stimulator mainframe holds one module for each channel. The modules are where different parameters are set, and where settings and information such as voltage, current or frequency are displayed.

The stimulator can be operated manually or from iox2 software. In the latter case, all settings can be made and saved in iox2 configuration files. A wide range of stimulation protocols can be created and automatically executed.


settings:

All stimulation parameters are adjustable:
- main frequency
- stimulation in current or voltage
- pulse amplitude
- pulse width
- pulse polarity (positive, negative, biphasic or alternative)
- type of stimulation (continuous, by train, manually)
- duration of the train or pulse number in the train (if train mode is used)

 