emka TECHNOLOGIES S.A.
59, bd. Général Martial Valin
75015 Paris - France
tel: + 33 (0)1 40 60 76 00
fax: +33 (0)1 40 60 65 55
e-mail: emka@emka.fr
emka TECHNOLOGIES Inc.
307 Annandale Road, suite 203
Falls Church, VA 22042 - USA
tel: +1 (703) 237-9001
fax: +1 (703) 237-9006
e-mail: emkatech@emkatech.com
      site map  
      newsletter
      contact us  
      legal info
  HomeCompanyProductsApplicationsServices
 
emka TECHNOLOGIES' hardware and software products for preclinical research
    what we do

  our products
  software software
  hardware hardware
    isolated organ systems
     tissue baths
     ios4 automate
     isolated heart
     vessel myographs
     stimulation
     thermal regulation
     perfusion
    pulmonary systems
    amplifiers
    usb acquisition
    noninvasive telemetry
    easyMATRIX
    implantable telemetry
    rodent telemetry
    drug delivery implant
    flowmeters
    transducers
    pv systems
    food intake monitoring
    rodent ecg restrainer
    noninvasive ecg & bp
    nibp from small rodents
  21 cfr part 11 21 cfr part 11
  arrange a demo arrange a demo
  request a quote request a quote
  latest projects latest projects
 
microvessel myograph
 

2-bath myograph (myo2)

The myograph is designed for the study of microvessels with diameters between 100 µm and 2 mm, and maximum length of 3.5 mm. The small vessels are mounted between two tungsten wires fixed to two supports.

the myograph includes: Download the micro vessels myographs brochure.

  • two independent 10 ml baths, with drain hole and frit glass bubbler to provide oxygenation and mixing of liquids.
  • Plexiglas body with internal passages for circulation of heating fluid.
  • two tubes per bath, one to bring physiological liquid (pushed by carbogen) and the other to control liquid level (excess drawn by vacuum source). Physiological liquid is heated in a coil.
  • two high-sensitivity isometric transducers:
    • measuring range: +/- 10 g
    • maximum acceptable overload: +/- 20 g
    • full-scale output: 10 mV/V  
    • combined error (nonlinearity, hysteresis,
      repeatibility: +/-1% of PE)
    • natural frequency response: 600 Hz
    • excitation voltage: 10 V
  • two precision Vernier positioners.
  • two pairs of tungsten wire supports. One support is removable, so vessels can be mounted outside of the bath.
  • tungsten wire diameter: 25 µm, 50 µm or 100 µm.

available options:

  • bath sizes: 2 x 3 ml, 2 x 5 ml, 2 x 10 ml, 1 x 20 ml bath.
  • AMPLI-SG2 two-channel amplifier.
  • THERMOREG hot water circulation and physiological preheating system.
  • iox software for data acquisition and analysis.

 

1-bath myograph (myo1)

Same as myo2 (above), but with one bath only. Can be upgraded to myo2 (the bath assemblies are interchangeable).

 
ask for a quote
» ask for a quote
related software : iox2
related hardware : amplifiers - thermal regulation - automated washes



  subscribe to emka TECHNOLOGIES' rss feed!


microvessel myograph
 
 
 
© 2004-2012 emka TECHNOLOGIES S.A. - site version 4.1
developed by kic - designed by f. lagny | site last update : May 18, 2012