emka TECHNOLOGIES' hardware and software products for preclinical research
    what we do

  our products
  software software
  hardware hardware
    isolated organ systems
     tissue baths
     ios4 automate
     isolated heart
     vessel myographs
     stimulation
     thermal regulation
     perfusion
    pulmonary systems
    amplifiers
    usb acquisition
    noninvasive telemetry
    easyMATRIX
    implantable telemetry
    rodent telemetry
    drug delivery implant
    flowmeters
    transducers
    pv systems
    food intake monitoring
    rodent ecg restrainer
    noninvasive ecg & bp
    nibp from small rodents
  21 cfr part 11 21 cfr part 11
  arrange a demo arrange a demo
  request a quote request a quote
  latest projects latest projects
 
stc4050
 

single channel stimulator:

Constant current stimulator with output insulation and maximum power of 40 mA/50 V (2 W). Produces single or dual pulses. In dual pulse mode, the second pulse has the same electrical characteristics as the first pulse:

operating modes:

The stimulator can be triggered manually to deliver

  • one isolated pulse or a sequence of two isolated pulses
  • a train of single or dual pulses of programmable duration
This stimulator can also operate continuously.

technical data:

  • Pulse width: from 1 to 10 ms
  • Pulse frequency: from 0.1 to 100 Hz in 3 ranges: (0.1 to 1 Hz), (1 to 10 Hz), (10 to 100 Hz)
  • Pulse shape: positive square or negative square through polarity inversion
  • Delay between first and second pulse: from 0.01 to 10 s in 3 ranges: (0.01 to 0.1 s), (0.1 to 1 s), (1 to 10 s)
  • Pulse train duration: from 0.01 to 100 s in 4 ranges: (0.01 to 0.1 s), (0.1 to 1 s), (1 to 10 s), (10 to 100 s)
  • Oscilloscope synchronization delay: from 5 µs to 0.5 ms in 2 ranges: (5 to 50 µs), (50 µs to 0.5 ms)

operating controls:

front panel settings are:

  • Operating mode (train of pulses, continuous pulse, isolated single or dual pulse)
  • Oscilloscope synchronization delay
  • Pulse train mode and pulse width
  • Second pulse delay
  • Frequency
  • Polarity inversion
  • Power
  • Manual trigger

coupling to other equipment
This stimulator can be triggered by an external control box or by iox2 software. It also can drive the 8-channel stc8808 stimulator.

The signal from the stimulator can be amplified up to 800 mA/80 V using the 1-channel stc4050 amplifier or the 2-channel sta2808 amplifier (in this latter case, both channels are synchronized).

Dimensions: 150 x 260 x 280 mm (HxWxD).
Weight: 2.8 kg.

 

 
ask for a quote
» ask for a quote
related software : iox2
related hardware : isolated organ systems


  subscribe to emka TECHNOLOGIES' rss feed!


stc4050
 
 
 
© 2004-2012 emka TECHNOLOGIES S.A. - site version 4.1